Daily Mixer Inspection

Procedure 36 of 40 · Chapter 23 · §23.1.1

1 table 0 notes

Table 1

Inspection ItemMethodAlert ThresholdCritical ThresholdAction if Critical
Seal leakageVisualWeepingStreamingImmediate shutdown
Bearing temperatureIR thermometer>20°C above ambient>80°C (greased)Shutdown; inspect bearing
Vibration (velocity)Vibration pen>4.5 mm/s RMS>7.1 mm/s RMSShutdown; check alignment
Gearbox temperatureIR thermometer>15°C above baseline>90°C housingShutdown; check oil
Coupling conditionVisualMinor wearCracked/looseReplace before restart
Oil conditionVisual colorDarkeningMilky/metallicSample for analysis
Safety devicesFunctionalN/AInterlock bypassedCorrect before operation